Energy Saving with Two-Speed Motors in Pumping Stations

two-speed asynchronous motor variable number of poles rated power power factor

Authors

  • F. N. Toychiev
    Toychiev@gmail.co
    Senior Lecturer of the Department of Power Supply, TSTU
  • H. J. Achilov Tashkent Institute of irrigation and Agricultural Engineers of Bukhara branch of the Department of energy supply in agriculture and water economy asisstenti
  • H. N. Mamadiev Tashkent Institute of irrigation and Agricultural Engineers of Bukhara branch of the Electricity supply and renewable energy
  • Zh. B. Razhabov Tashkent Institute of irrigation and Agricultural Engineers of Bukhara branch of the Electricity supply and renewable energy
December 2, 2021

Downloads

This article shows the easiest and relatively inexpensive way to adjust the speed of rotation of induction motors - the ability to adjust the speed using two-speed asynchronous motors with a variable number of poles. Comparison and analysis of the main energy characteristics of two-speed single-winding and two separate asynchronous motors is carried out. Based on the data obtained, two-speed motors with a variable number of poles are proposed as an asynchronous motor as part of an electric drive.